Alarm Notification Types

Reference Number: AA-02142 Views: 25 0 Rating/ Voters

When enabled, the LumenVox Manager can send a number of different types of SNMP Trap notifications.

These notifications are typically messages or alerts to indicate some change in state of some monitored object, or a heartbeat message to indicate that the LumenVox Manager is still running. These Trap notifications are sent to all configured TRAP_SERVERS using SNMP v2c protocol.

Here is a complete list of the Types of Trap message that can be generated by LumenVox:


Trap Type






This message type is sent to all registered   TRAP_SERVERS at the specified HEARTBEAT_INTERVAL. When this HEARTBEAT_INTERVAL   is set to 0 (the default), no heartbeat messages will be sent.

This notification type is sent with INFO severity   and does not include a CorrelationID field (since it is not an alarm or a   clear notification). A count of the current heartbeats sent is sent within   the lvTrapAdditionText field.

Specified TRAP_SERVERS can be configured to expect   these trap notifications, and if no heartbeat is received within a certain   time period, this can be used to indicate a failure of the LumenVox server,   or LumenVox Manager Service – either of which should be investigated.




There are 3 thresholds (MINOR, MAJOR and CRIT) that   can be defined for this type of alarm (in manager.conf). When system CPU   utilization exceeds one of the specified thresholds, the corresponding trap   notification will be sent with the appropriate severity.




Sent when the corresponding lvAlarmCpuOverload alert   has abated – when system CPU use has fallen below the specified threshold.




There are 3 thresholds (MINOR, MAJOR and CRIT) that   can be defined for this type of alarm. When system memory utilization exceeds   one of the specified thresholds, the appropriate corresponding trap   notification will be sent with the appropriate severity.




Sent when the corresponding lvAlarmMemoryOverload   alert has abated – when system memory use has fallen below the specified threshold




When communication with one of the configured LumenVox   services is lost, an alert of this type will be generated.

If the service is designated as the Primary (first   listed) instance, then a message will indicate this.

Also, if alternate servers of this type remain available,   this will be indicated, as well as affect the notification severity. When alternate(s)   are available, the message will have MINOR severity. When no alternate is available,   the message will have CRIT severity.




Sent when the corresponding lvAlarmCommsFailure   alert has been removed – when the communication link is restored.




This message is generated whenever an attempt to   request ASR or TTS licenses is made by the Media Server service.

The notification will indicate whether the failure   was due to a TTS license request or an ASR license request. The message severity   will be CRIT




Sent whenever the corresponding lvAlarmNoLicense   alert has cleared – once a request for the appropriate ASR or TTS license   type has succeeded.




This is not implemented in the current version (for   future use)




This is not implemented in the current version (for   future use)




There are 3 thresholds (MINOR, MAJOR and CRIT) that   can be defined for this type of alarm.

When free disk space drops below one of the specified   thresholds, the appropriate trap notification will be sent with the   corresponding severity.

Note that the disk drive / partition being   monitored is the one associated with the LumenVox Manager’s LVLOGS folder –   wherever the manager’s logs are stored. We recommend that systems are   configured to store their log files to the same disk / partition for all   LumenVox services to avoid any confusion, since only this disk/partition is   monitored.




These messages will be sent when the corresponding   lvAlarmLowDiskSpaceAlert alert has abated – whenever free disk space has been   raised above the specified threshold.


Note that these trap alert types are defined within the LUMENVOX-SNMP-MIB definition document that can be imported into many standard SNMP systems. The definition of these notifications is shown here:

See the Trap Message Contents article for additional information about the structure of Variable Bindings that are sent within these notification messages.